Coverage: Varies on type of surface you're coating. Contact Support
POLYASPARTIC 85 (SLOW CURE) 2 COMPONENT | 1 TO 1 MIX RATIO
PRODUCT DESCRIPTION
E2U Polyaspartic (Slow Cure) has essentially zero odor. The ideal applications are hospitals, restaurants, kennels, veterinary facilities, health care facilities, and garages etc. It is a two component, extremely chemical resistant. and non-yellowing aliphatic Polyaspartic. It features high gloss, high build, and a cure time of 48 hours, and generally return to service in 72 hours. It can be installed in extremely high or low temperatures. E2U Polyaspartic Slow Cure is the ideal product for use on large scale projects or where an excessive amount of "cut in" is required.PRODUCT DATA
Volumetric Ratio: 1 to 1
Volumetric Solids: 85%
Coverage: Varies on type of surface you're coating. Contact Support
Application Temperature: 35°-100°F
Thinning: Not Required
Pot Life: 5-10 min.
Working Time on Floor: 20 to 30 min.
Cure Time (walking) : 7 Days
Return to Service(vehicle): 7-10 Days
Critical: Re-Coat: Time
USDA Food & Beverage: Meets Req.
AVAILABLE COLORS
• Light Gray • Medium Gray • Dark Gray • White • Black • Tan • Beige • Mocha • Tile Red • Safety Red • Safety Blue • Safety Green • Safety YellowAPPLICATIONS
• Pharmaceutical • Food Prep/Kitchens • Garage Floors • Restrooms • Manufacturing plants • Aisle ways • Clean Rooms • Auto showrooms • Schools • Laboratories • Basements • Kennels • Veterinary facilities • Locker rooms • Ramps • Health Care facilities • Loading docks • Car wash facilitiesPACKAGING
2 GALLON KITS
PART A: 1 Gal PART B: 1 Gal10 GALLON KITS
PART A: 5 Gal PART B: 5 GalADVANTAGES
• High Gloss (just like glass) & Build • 4x more abrasion resistant than epoxy • Non-yellowing • Chemical, scratch, abrasion resistant • Easy mixing ratio (1:1) • Solvent FREE • Cure at temperatures just above Freezing • Does not support growth of bacteria or fungus.CONCRETE PREPARATION
Before coating is applied, concrete must be: • Dry – No wet areas • Clean – Contaminants removed • Profiled – 30 Grit Diamond Grinding • Sound – All cracks and spalled areas repaired Mechanical preparation is the preferred method of preparing concrete for coating application. Shot-blasting, diamond grinding, are all acceptable methods.PATCHING
Voids, cracks and imperfections will be seen in finished coating if the concrete is not patched correctly. Patch concrete with Easy Patch. After the patching material is cured, diamond grind patch. If a non-patching material is used, contact a technical representative for a compatible and approved alternative.MOISTURE VAPOR EMISSIONS WARNING
All concrete floors without effective moisture vapor barrier are subject to possible moisture vapor transmission that may cause blistering and failure of the coating system. It is the applicator’s responsibility to conduct calcium chloride and relative humidity probe testing to determine vapor emissions prior to applying any coating. Epoxy2U can supply moisture remediation products, MVB15 (MOISTURE VAPOR BARRIER). EPOXY2U, sales agents will not be responsible for coating failures due to undetected moisture vapor emissions.MIXING
The ratio of Polyaspartic 85 is 1 Part A to 1 Part B by volume. Mix for 1 full minute using a slowspeed drill, scraping the bottom and sides of the mixing container. Mix only that amount which can be spread in 30 minutes.CLEAN UP
While in an un-reacted state, may be cleaned up with water and degreaser. Isopropyl alcohol or acetone may be needed once the resin begins hardening. Lastly, a strong solvent like methylene chloride may be required if resin is nearly set up.NOTE:
High Humidity will accelerate work time dramatically. Be cautious when applying on High Moisture Days. POLYASPARTIC 85 SLOWCURE.NOTE:
When recoating Existing epoxy or Sealer Coats refer to "E2U Instructions for concrete surface prep and recoat.WARNING!
SLIP AND FALL PRECAUTIONS
OSHA and the American Disabilities Act (ADA) have now set enforceable standards for slip resistance on pedestrian surfaces. The current coefficient of friction required by ADA is .6 on level surfaces and .8 on ramps. E2U Flooring recommends the use of angular slip-resistant aggregate in all coatings or flooring systems that may be exposed to wet, oily or greasy conditions. It is the contractor and end users’ responsibility to provide a flooring system that meets current safety standards. E2U or its sales agents will not be responsible for injury incurred in a slip and fall accident. Handling Precautions Use only with adequate ventilation. Appropriate cartridge-type respirator must be used during application in confined areas. Avoid contact with skin. Some individuals may be allergic to epoxy resin. Protective gloves and clothing are recommended.WARRANTY
E2U products are warranted for one year after date of purchase. Please refer to the Limited Material warranty for additional clarification.Weight | N/A |
---|---|
Dimensions | N/A |
size | 2G Kit, 10G Kit |