Novolac Chemical Containment Epoxy
$372.95 – $1,901.75
E2U Novolac Chemical Containment Epoxy kit is a two component, 100% solids kit and extremely chemical-resistant to many acids, alkali, and other harsh chemicals. It can be applied in cool damp conditions as well as can be used in areas that are subject to extreme heat. Silica, sand, or color quartz can be broadcast into E2U Novolac Chemical Containment Epoxy. It can be used on new floors as well as for refurbishing existing surfaces.
- Coverage:
- 100 sq. ft./gal. at 16 mil.
The uniqueness and universality of E2U Novolac Chemical Containment Epoxy chemistry facilitates the applications where USDA Food & Beverage and other regulatory requirements must be obtained. Ideal areas of use include: secondary containment, chemical and waste treatment plants, gas and electric utilities, power plants, textile mills, solvent storage, pump pads, trenches, and more.
- - Essentially odorless
- - Can be applied in cool/damp conditions
- - Can be used in areas that are subject to extreme heat
- - VOC compliant
- - High color stability
- - High gloss
- - No amine blush
- - No permeability
- - Extremely chemically resistant
- 100 sq. ft./gal. at 16 mil.
NOVOLAC CONTAINMENT EPOXY 2 COMPONENT, 2 TO 1 MIX RATIO
PRODUCT DESCRIPTION
E2U Novolac Containment Epoxy is a two component, 100% solids and extremely chemical resistance to many acid, alkali and other harsh chemicals. It can be applied in cool damp conditions as well as can be used in areas that are subject to extreme heat. Silica Sand or Color Quartz can be broadcast into E2U Novolac Containment Epoxy. It can be used on new floors as well as for refurbishing existing surfaces.Product Data
Volumetric Ratio: 2 to 1 Solids.: 100% (+ or - 1%) Coverage: 50 SF/gal. at 32 mil Application Temperature: 40-90°F Thinning : Not Required Pot life: 3-5 min. Working Time on Floor: 20-30 min. Cure Time: 12 hours (walking) 24 hours (light traffic) Full Cure: 5 to 7 days Critical Re-Coat Time: 12 hrs. Shelf life: 12 months. USDA Food & Beverage: Meets ReqColor Pigments
E2U Novolac Containment Epoxy is available with standard premixed colors.Available Colors Include:
• Clear • Light Gray • Medium Gray • Dark Gray • White • Black • Tan • Beige • Tile Red • Safety Red • Safety Blue • Safety Green • Safety YellowAPPLICATIONS
The uniqueness and universality of E2U Novolac Containment Epoxy chemistry facilitates the applications where USDA Food & Beverage and other regulatory requirements must be obtained. Ideal areas of use include: Secondary containment, Chemical and waste treatment plants, Gas and electric utilities, Power plants, Textile mills solvent storage, pump pads, trenches and more.ADVANTAGES
• Essentially odorless • Can be applied in cool damp conditions • Can be used in areas that are subject to extreme heat • VOC Compliant • High color stability • High gloss • Extremely Chemical resistant • No amine blush • low viscosity • low permeabilityPHYSICAL PROPERTIES
Packaging
1.5 Gallon Kits:
Part A : 1 GAL Part B : 1/2 GAL15 Gallon Kits:
Part A : 10 GAL Part B : 5 GALCONCRETE PREPARATION
Before coating is applied, concrete must be: • Dry – No wet areas • Clean – Contaminants removed • Profiled – Surface etched • Sound – All cracks and spalled areas repaired Note: Mechanical preparation is the preferred method of preparing concrete for coating application. Shot-blasting, diamond grinding, scarifying and scabbling are all acceptable methods.PATCHING
Voids, cracks and imperfections will be seen in finished coating if the concrete is not patched correctly. Patch concrete with E2U Patch. After the patching material is cured, diamond grind patch. If another patching material is used, contact a E2U technical representative for a compatible and approved alternative.TESTING
All surfaces are not the same. It is recommended that a sample area be done before the start of the project. The test should be done on-site, using the proposed method by the assigned applicator to insure proper adhesion and color. A sample area should also be done on any existing coatings to determine if any contaminants exist or if delaminating will occur.MIXING
The ratio of E2U Novolac Containment Epoxy to 1. That is, two parts A (resin) to one part B (hardener). Mix the following with a drill and mixing paddle. Note: If using a drill mixer, use a low speed (not to exceed 300 rpm) to prevent air entrapment. 1. Premix 1 gallon of Part A for 30-45 seconds. 2. Add 1/2 gallon of Part B and mix for another 60-90 seconds. 3. E2U Epoxy is designed to be immediately poured on the floor. Leaving mixed product in the container will greatly reduce pot life. Once poured out on the floor, 15-20 minutes of working time can generally be expected.CLEAN UP
E2U Epoxy, while in an un-reacted state, may be cleaned up with hot water and degreaser. Isopropyl alcohol or acetone may be needed once the resin begins hardening. Lastly, a strong solvent like methylene chloride may be required if resin is nearly set up.APPLICATION INSTRUCTIONS
Application of E2U Novolac Containment Epoxy for a nominal 20 to 30 mil coating system is applied in two coats and in one pass as a top coat. For estimation purposes, use 200 SF per gallon in either case. 1. Always apply in descending temperatures. Concrete is porous and traps air. In ascending temperatures (generally mornings) the air expands and can cause out gassing in the coating. It is safer to apply coatings in the late afternoon, especially for exterior applications. 2. Optimum ambient temperature should be between 55-90°F during application. Note: Cure times are affected by ambient and slab temperatures. Temperatures of 55°F and lower can slow cure times. Temperatures of 85°F and higher will speed up working and times. 3. Mix three gallons of resin using above mixing instructions. 4. Apply approximately 200 SF per gallon (150 SF per gallon for a top coat over Industrial Quartz systems) by immediately pouring out on surface in a ribbon, while walking and pouring at the same time until bucket is empty. 5. Using a squeegee on a pole, pull E2U Epoxy over substrate. As a first coat over bare concrete, pull resin as thin as possible while still wetting out concrete and uniformly covering surface. This allows trapped air to escape more easily. To apply in a single coat over an Industrial Epoxy system, pull at about 200 SF per gallon. 6. Using a 3/8” non-shedding phenolic (plastic) core paint roller, roll coating forwards and backwards. 7. Lastly, back roll in the opposite direction as step 6. 8. Apply second coat by repeating steps 1-7 the within 12 hours. Failure to recoat during this window may result in fish eyes. Always sand floor after 12 hours before recoat.NOTE:
Above instructions are for standard appications. For full chemical containment ALWAYS confer w/E2u technical support for specific application recommendationsWARNING! SLIP AND FALL PRECAUTIONS
OSHA and the American Disabilities Act (ADA) have now set enforceable standards for slip resistance on pedestrian surfaces. The current coefficient of friction required by ADA is .6 on level surfaces and .8 on ramps. E2U Flooring recommends the use of angular slip resistant aggregate in all coatings or flooring systems that may be exposed to wet, oily or greasy conditions. It is the contractor and end users’ responsibility to provide a flooring system that meets current safety standards. E2U or its sales agents will not be responsible for injury incurred in a slip and fall accident.Handling Precautions
Use only with adequate ventilation. Appropriate cartridge-type respirator must be used during application in confined areas. Avoid contact with skin. Some individuals may be allergic to epoxy resin. Protective gloves and clothing are recommended.WARRANTY
E2U products are warranted for one year after date of purchase. Please refer to the Limited Material warranty for additional clarification.Weight | 1 lbs |
---|---|
Size | 1.5 GAL, 3 GAL, 15 GAL |
Color | Clear, White, Light Gray, Medium Gray, Dark Gray, Black, Tan, Mocha, Beige |