Epoxy 4500 – UV Resistant
$36.68 – $1,224.00
E2U Epoxy 4500 is a two component, 100% solids, Zero VOC, high performance modified cycloaliphatic epoxy concrete floor coating system. Its epoxy chemistry provides excellent bonding characteristics. E2U Epoxy 4500 is UV resistant and essentially odorless. It has a long working time and has high gloss, color stability.
- Coverage:
- 150 / 200 SF/Gal – This particular epoxy has an extended work time of up to 45 min., very strong UV Resistance and is ideal for a top coat sealer clear or pigmented.
The uniqueness and universality of E2U Epoxy’s chemistry facilitates the applications where USDA Food & Beverage and other regulatory requirements must be obtained. Areas of use include: garage floors, showrooms, hotel lobbies & entryways, exhibition halls, restaurants, retail/commercial venues.
- - Essentially odorless
- - ZERO VOC
- - High gloss/color stability
- - Low viscosity
- - Long pot life and working time
- - Chemically resistant
- - No amine blush
- - Modified to be resistant to ambering
- 150 / 200 SF/Gal – This particular epoxy has an extended work time of up to 45 min., very strong UV Resistance and is ideal for a top coat sealer clear or pigmented.
EPOXY 4500 UV RESISTANT
PRODUCT DESCRIPTION
E2U Epoxy 4500 IS A TWO component, 100% solids, Zero VOC, high performance modified cycloaliphatic epoxy concrete floor coating system. It's epoxy chemical provides excellent bonding characteristics. E2U Epoxy 4500 is UV resistant and essentially odorless. It has a long working time and has high gloss, color stability.PRODUCT DATA
Volumetric Ratio: 2 to 1 Solids: 100%(+/- 1%) Coverage: 100 sqft/gal. at 16 ml, 200 sqft/gal. at 8 ml Application Temperature: 55°-90°F Thinning: Not Required Pot Life: 5 min Working Time on Floor: 45-60 min Cure Time: 12 to 16 hours Full Cure: 5 - 7 days Critical Re-Coat Time: 12 hrs Shelf Life: 12 months USDA Food & Beverage: Meets Req.AVAILABLE COLORS
• Clear • Light Gray • Medium Gray • Dark Gray • White • Black • Tan • Beige • Tile Red • Safety Red • Safety Blue • Safety Green • Safety YellowAPPLICATIONS
Garage floors • Clean rooms • Manufacturing facilities • Automotive showrooms • Commercial kitchens • Grocery Stores Laboratories • Basements • Kennels • Restrooms • Locker rooms • Aisle waysADVANTAGES
• Essentially odorless • ZERO VOC • High Gloss, & color stability • Low Viscosity • Long Pot Life & Working time. • Beige • Tile Red • Safety Red • Safety Blue • Safety Green • Safety Yellow • Laboratories • Basements • Kennels • Restrooms • Locker rooms • Aisle ways • Chemically Resistant • No amine blush • Modified to help with UV resistancePACKAGING
1.5 GALLON KITS
PART A: 1 Gal PART B: 1/2 Gal3 GALLON KITS
PART A : 2 GAL PART B : 1 GAL15 GALLON KITS
PART A: 10 GAL PART B: 5 GALCONCRETE PREPARATION
Before coating is applied, concrete must be: • Dry – No wet areas • Clean – Contaminants removed • Profiled – Surface must be diamond ground to a CSP (Concrete Surface Profile) rating of “2”... Roughly the feel of 100 Grit Sandpaper. • Sound – All cracks and spalled areas repaired Note: Mechanical preparation is the preferred method of preparing concrete for coating application. Shot-blasting, diamond grinding, scarifying and scab-bling are all acceptable methods.REPAIR CRACKS
Voids, cracks and imperfections will be seen in finished coating if the concrete is not patched correctly. Patch concrete with E2U Rapid Mender after patching material is cured, diamond grind patch. If another patching material is used, contact an E2U technical representative for a compatible and approved alternative.MOISTURE VAPOR EMISSIONS WARNING
All concrete floors without effective moisture vapor barrier are subject to possible moisture vapor transmission that may cause blistering and failure of the coating system. It is the applicator’s responsibility to conduct calcium chloride and relative humidity probe testing to determine vapor emissions prior to applying any coating. E2U can supply moisture remediation products MVB15 (MOISTURE VAPOR BARRIER) that are up to 15 lbs. E2U sales agents will not be responsible for coating failures due to undetected moisture vapor emissions.MIXING
The ratio of epoxy 4500 is 2 to 1. That is, two parts A (resin) and one part B (hardener). Mix the following with a drill and mixing paddle. Note: If using a drill mixer, use a low speed (not to exceed 300rpm) to prevent air entrapment. E2U Epoxy is designed to be immediately poured on the floor. Leaving mixed product in the container will greatly reduce pot life. Once poured out on the floor, 45-60 minutes of working time can generally be expected.CLEAN UP
While in an un-reacted state, may be cleaned up with hot water and degreaser. Isopropyl alcohol or acetone may be needed once the resin begins hardening. Lastly, a strong solvent like methylene chloride may be required if resin is nearly set up.APPLICATION INSTRUCTIONS
Application of E2U Epoxy 6150 for a nominal 8 to 16 mil coating system is applied in a single coat. For estimation purposes, use 200 SF per gallon in either case. 1. Always apply in descending temperatures. Concrete is porous and traps air. In ascending temperatures (generally mornings) the air expands and can cause out gassing in the coating. It is safer to apply coatings in the late afternoon, especially for exterior applications. 2. Optimum ambient temperature should be between 55-90°F during applica-tion. Note: Cure times are affected by ambient and slab temperatures. Temperatures of 55°F and lower can slow cure times. Temperatures of 85°F and higher will speed up working and times. 3. Mix 2gal kit of Epoxy 6150 using above mixing instructions. 4. Apply approximately 200 SF per gallon by immediately pouring out on surface in a ribbon, while walking and pouring at the same time until bucket is empty. NEVER turn bucket upside down and allow to drain. 5. Using a squeegee on a pole, pull E2U Epoxy 6150 over substrate. As a first coat over bare concrete, pull resin as thin as possible while still wetting out concrete and uniformly covering surface. This allows trapped air to escape more easily. 6. Using a 3/8” non-shedding phenolic (plastic) core paint roller, roll coating for-wards and backwards.SPECIAL NOTE:
ALL Epoxies manufactured by Epoxy2U are NOT UV Stable and can and WILL amber and discolor when exposed to UV light.WARNING! SLIP AND FALL PRECAUTIONS
OSHA and the American Disabilities Act (ADA) have now set enforceable standards for slipresistance on pedestrian surfaces. The current coefficient of friction required by ADA is .6 on level surfaces and .8 on ramps. E2U Flooring recommends the use of angular slip-resistant aggregate in all coatings or flooring systems that may be exposed to wet, oily or greasy conditions. It is the contractor and end users’ responsibility to provide a flooring system that meets current safety standards. E2U or its sales agents will not be responsible for injury incurred in a slip and fall accident.Handling Precautions
Use only with adequate ventilation. Appropriate cartridge-type respirator must be used during application in confined areas. Avoid contact with skin. Some individuals may be allergic to epoxy resin. Protective gloves and clothing are recommended.WARRANTY
E2U products are warranted for one year after date of purchase. Please refer to the Limited Material warranty for additional clarification.Weight | 1 lbs |
---|---|
Dimensions | N/A |
Size | 48 OZ, 1.5 GAL, 3 GAL, 15 GAL |
Color | Clear, White, Light Gray, Medium Gray, Dark Gray, Black, Tan, Mocha, Beige, Tile Red, Tan |